3. APPLIANCE DATA
This product uses fuel effect pieces and gaskets containing Refractory Ceramic Fibres
(RCF), which are man-made vitreous silicate fibres. Excessive exposure to these
materials may cause irritation to eyes, skin and respiratory tract. Consequently, it is
important to take care when handling these articles to ensure that the release of dust is
kept to a minimum. To ensure that the release of fibres from these RCF articles is kept to
a minimum, during installation and servicing we recommend that you use a HEPA
filtered vacuum to remove any dust and soot accumulated in and around the fire before
and after working on the fire. When replacing these articles we recommend that the
replaced items are not broken up, but are sealed within a heavy duty polythene bag,
clearly labelled as RCF waste. This is not classified as “hazardous waste” and may be
disposed of at a tipping site licensed for the disposal of industrial waste. Protective
clothing is not required when handling these articles, but we recommend you follow the
normal hygiene rules of not smoking, eating or drinking in the work area and always
wash your hands before eating or drinking.
This appliance does not contain any component manufactured from asbestos or asbestos
related products.
The appliance data label is located on a plate at the base of the fire. This can be seen by
lowering the bottom front cover of the front surround.
Gas Natural (G20)
Propane (G31)*
Inlet Pressure 20mbar 37mbar
Input - Max. (Gross) 5.1kW (17,400 Btu/h) 5.1kW (17,400 Btu/h)
Input - Min. (Gross) 2.2kW (7500 Btu/h) 3.5kW (11940 Btu/h)
Burner Test Pressure (Cold) 18.2 ± 0.75mbar (7.3 ± 0.3in
w.g.)
35.5 ± 0.75mbar (14.25 ±
0.3in w.g.)
Gas Connection 8mm pipe 8mm pipe
Burner Injector Bray Cat. 18 Size 300 Bray Cat. 18 Size 140
Pilot & Atmosphere
Sensing Device
SIT Ref. OP NG9030 SIT Ref. OP LPG9222
Ignition Piezo Electric. Integral with
Gas Tap
Piezo Electric. Integral with
Gas Tap
Aeration Non-adjustable Non-adjustable
* When converted using kit 0595201