INSTALLER’S GUIDE
Page 19
Figure 13. Flue Restrictor
Figure 12. Fireback Spacers
12. The appliance is supplied with two fireback
spacers. Do not fit the fireback spacers if the fire is
to be installed into a precast or clay flue block
system as in section 4.2.3.These should extend
backwards to ensure sufficient clearance from the
back of the fireplace. Remove the label and retaining
screws from the rear sides of the hotbox. Position
the fireback spacer as shown in figure 12. Secure the
fireback spacers using the screws removed
previously and the two supplied with the fire.
13. This appliance is supplied with a flue restrictor
for use where the flue draught is excessive. The
restrictor must NOT be fitted where a
precast flue or a flue liner is used. For
all other installations the restrictor
should be fitted. There may however,
be certain exceptional circumstances
where fitting the restrictor causes the
fire to fail the spillage test. In such
cases the restrictor will have to be
removed. After removal conduct the
spillage check again.
The restrictor is packed loose with
the appliance and is fixed with two
screws. See figure 13.