INSTALLER’S GUIDE
Page 34
Figure 39. Smoke match tube position
12.2 Check for Spillage
A spillage check must be made before leaving the installed appliance with the
customer. Make this with all the ceramic pebbles in position.
1. Close all doors and windows in the room containing the appliance.
2. Light the appliance and set the control to the ‘High’ position.
3. Leave the appliance on for five minutes.
4. The smoke match should be placed horizontally into the hotbox at the right hand side.
(See figure 39).
The installation is satisfactory if the smoke is drawn into the appliance.
If the smoke is not drawn into the appliance leave the appliance alight at the maximum
setting for a further ten minutes and then
repeat the test. If the smoke is still not
drawn into the appliance inspect the
sealing to the fireplace surround. If the
sealing is satisfactory but the appliance is
installed with the flue restrictor (see
section 7 point 13) remove the restrictor,
reseal the appliance and retest. If smoke is
still not drawn into the appliance
disconnect the appliance and seek
expert advice.
5. If the above test is satisfactory open all
internal connecting doors, hatches, etc. in
the room. Keep all doors and windows
that open to the outside of the building
closed. Recheck for spillage as above. If
an extractor fan is installed in the same
room as the appliance or a connecting
room, check that spillage does not occur
with the fan operating and all doors and
other openings between the fan and the
appliance open.
If the smoke is drawn into the appliance, continue with the installation. If the test is not
satisfactory disconnect the appliance and advise the customer of the cause of failure.